... | ... | @@ -285,14 +285,14 @@ mydata.header[3].UB # return dictionary of UB metadata |
|
|
- Check if main shutter and branch shutter are open. If any shutter cannot be openned, Check beamline EPS and call stuff.
|
|
|
- Check if ID and mono energy setpoints are consistent.
|
|
|
- Check beam on the exit slit camera from m3r_align panel.
|
|
|
- If there is no beam and piezo voltage is very high (-12V or 40V), try tweak it back to zero.
|
|
|
- If there is no beam and piezo voltage is very high (-12V or 40V), try tweaking it back to zero.
|
|
|
|
|
|
2. `m3r_align` doesn't work.
|
|
|
- This happens when the code had hard time to determine where the peak was. Try tweak the piezo voltage back to zero and adjust m3r pitch.
|
|
|
- When the photon energy is too high (> 2.1 keV) or the mono and ID energies are very different, photon counts can be low. Try increase exposure time (t(s)) of the camera.
|
|
|
- When the photon energy is too high (> 2.3 keV), or the mono and ID energies are very different, photon counts can be too low to determine the peak position. Try increasing exposure time (`t(s)` on the screen) of the camera.
|
|
|
|
|
|
3. ID gets stuck.
|
|
|
- change mode on the ID screen, wait until it's done, and change the mode back. This will reset the ID.
|
|
|
- Change mode on the ID screen (`IEXMachinePhysics.adl`), wait until it's done, and change the mode back. This will reset the ID.
|
|
|
|
|
|
|
|
|
|
... | ... | |